Charlotte Stonestreet
Managing Editor |
Home> | POWER TRANSMISSION | >Bearings | >Fan Solution |
ARTICLE
Fan Solution
19 October 2012
An inherent design fault on the bearing assembly of a large centrifugal fan that could have potentially caused a cement plant to reduce, or even stop production due to a failure to comply with dangerous emission regulations, has been resolved with the help of Brammer.Fan Solution

The leading supplier of maintenance, repair and overhaul (MRO) products and services provided engineering input, advice and a product application solution to allow operations to continue uninterrupted.
The solution was to replace the non-drive end bearing with an SKF CARB toroidal roller bearing, as well as introducing a regular cleaning routine. No bearings or housings have had to be replaced since the change, with an estimated cost saving of £15,000.
The solution was to replace the non-drive end bearing with an SKF CARB toroidal roller bearing, as well as introducing a regular cleaning routine. No bearings or housings have had to be replaced since the change, with an estimated cost saving of £15,000.
MORE FROM THIS COMPANY
- MAINTENANCE PRODUCTS GUIDE
- Brammer & CEJN connect
- Encouraging energy compliance
- Quick guide to VSD specification
- TURNKEY SYSTEMS
- Engineering service centre capability boosted
- Largest range & stock holding of bearings in Europe
- MRO products for hard environments
- Power transmission products
- In the shadow of Concorde…
RELATED ARTICLES
- TURNKEY SYSTEMS
- RAIL TEST RIG FOR AXLEBOX BEARINGS
- Things It's Worth Bearing in Mind
- World's Largest Bearing Test Rig Now Operational
- Clean Air Swiftly Supplied
- Efficiency In Tough Environments
- Capacity Boosted
- Bearings for Renewable Energy Applications
- UPGRADED ROLLER BEARING RANGE
- Bearings On Mission To Mars
OTHER ARTICLES IN THIS SECTION